![]() First, clean out the burner orifice properly.Now, have a look at the corrective actions. Again, when the diameter of the burner office is too small, the problem appears.Īlso, the low gas pressure in the inlet will occur light problems. If the burner of your fireplace is clogged with dirt, the burner will fail to light. Now let’s know the possible reasons for causing the problem. This is so annoying and such a significant obstacle to operating the appliance. ![]() Sometimes, the burner does not light after the pilot is lit. It would be better to contact customer service to do this. If the control valve is damaged, you must replace it.Tighten the thermocouple, and replace or connect it if needed.When the pilot lights, press the control knob for about 30 seconds. ![]() The control knob is not fully pressed in or pressed on long enough, the shutoff valve is not open, the damaged thermocouple or loose connection of it, and the damaged control valve could be the reason behind the issue. We also highlight the cause of this problem. No worries, the gas fireplace flame goes out troubleshooting will help you in this case. If you see that while the control knob is pressing, ODS lights, but the flame goes out. If there is a problem with the gas regulator, replace it.Place the control knob in the pilot position.Repeat this ignition operation until air is removed thoroughly. If air enters the gas line, removing it is not a big deal.When you press the ignition button, you must firmly push the control knob as well.Then properly open the equipment shutoff valve.At first, if you can see the gas supply off, carefully turn it in.Other possible causes are blocked ODS with specks of dirt, incorrect gas regulator setting, the control knob is not in the pilot position properly, low gas supply, the control knob is not firmly pressed in, etc.Īnyways, we also describe effective solution methods for this problem. ![]() Also, when air enters the gas line, no ignition problem creates. There are a few reasons behind this problem.Įither the gas supply is off, or the shutoff valve is completely closed. Sometimes it seems that the ignitor button is pressed, fireplace pilot/ODS sparks but no ignition. So, without any delay, go through our gas fireplace troubleshooting guide. Moreover, all the solution methods are effective and quick working. Here, you will find the clear causes for every problem and the active solution procedures for each of them.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |